Tag: Balcony Type Solar Collector | Balcony Split Solar Water Heater
Tag: Air Water Heat Pump | Air-Source Heat Pump Water Heater
Tag: Air Heat Pump | Air Heating Pump
Tag: Outdoor Cooker | Outdoor Cookware
Flue Type |
Forced Exhaust Type |
Forced Exhaust and Air-Supply Type |
Not safe enough The combustion product generated during combustio is emitted directly to the bathroom, and the air for combustion is taken from the bathroom too. It is easy to cause CO poisoning and insufficient oxygen supply, so it can’t be installed inside the bathroom. |
Much safer than flue type The combustion product generated during combustion is emitted out of the bathroom through a flue, but the air for combustion is still taken from the bathroom, which may cause hypoxia. It is highly suggested not to install this type of gas water heater inside the bathroom. The difference between the flue type and forced exhaust type is that the forced exhaust type has a fan to forcedly blow or vacuum the combustion product out of the bathroom through a flue, but the China flue mounted gas water heater is to naturally emit the combustion product out of the bathroom with a flue (not included, optional). Therefore the evacuation of the combustion product of the forced exhaust type is more complete than that of flue type. |
The safest of all The combustion product generated during combustion is forcedly emitted out of the bathroom through a flue, meanwhile the air for combustion is forcedly inhaled from outside through the flue, so it wouldn’t consume or pollute the air inside. It is the safest and the only type that can be installed inside the bathroom. |
|
|
|
Type |
JSD20-10M1 |
JSD24-12M1 |
JSD32-16M1 |
Rated heat load(kW) |
20 |
24 |
32 |
Rated capability of hot water supply (△T=25℃) |
10kg/min |
12kg/min |
16kg/min |
Rated gas pressure |
Liquefied petroleum gas 2800 pa |
||
Natural gas 2000 pa |
|||
Manufactured gas 1000 pa |
|||
Control method |
By outlet valve |
||
Exhaust method |
Flue type |
||
Applicable water pressure (Mpa) |
0.02-1.0 |
||
Gas entrance |
G1/2 or G3/4 |
||
Cold water inlet |
G1/2 |
||
Hot water outlet |
G1/2 |
||
Product size(mm) |
636×350×225 |
636×350×225 |
680×410×223 |
Package size(mm) |
735×405×300 |
735×405×300 |
780×468×300 |
Gross weight/net weight(kg) |
12.8/11.3 |
13.3/11.8 |
18.3/15.1 |
Container number 20'/40'/40'HQ |
320/660/768 |
320/660/768 |
250/530/620 |
JSD20-10M1/JSD24-12M1/JSD32-16M1 | JSD20-10P1/JSD24-12P1/JSD32-16P1 |
JSD12-6CL/JSD14-7CL/JSD16-8CL/JSD20-10CL | JSD12-6CR/JSD14-7CR/JSD16-8CR/JSD20-10CR |
JSD12-6CA/JSD14-7CA/JSD16-8CA | JSD12-6CC/JSD14-7CC/JSD16-8CC |