Introduction of Condensing Gas Boiler,
1. The temperature of the flue emission of condensing wall-hung boiler with a secondary heat exchanger is around 60℃. Temperature of an ordinary wall-hung boiler is generally above 160℃
2. At the bottom of the condensing gas boiler is a secondary heat exchanger and a condensing water drain. The condensing water drains from it during operation; while there is no condensing water drain in the ordinary wall-hung boiler
3. To distinguish a condensing gas boiler from others by the internal structure
(1) There is one condensing water pipe drain and a condensing water neutralization box
(2) There is a condensing water pipe drain and a condensing water neutralization box
Features of China Residential Wall Mounted Boiler
1. Condensing gas boiler has the function of timing reservation for one week.
2. It uses digital display of heating and water temperature, and large LCD screen to display working status.
3. Condensing boiler is with self-detection functions to indicate corresponding security protection code.
4. Control the strength of the fire as per the thermal load needs, so as to realize self control of hot water constant temperature.
5. Ionic fire failure protection function to ensure gas is cut off when fire fails.
6. Heating and circulating hot water adopt the same system, and they can interchange freely.
7. Protection against extreme temperature to prevent boiler getting too hot and damaged.
8. It is with automatic bypass protection function to supplement water when tube gets blocked through the bypass, so as to avoid heating without water.
9. Condensing gas boiler is with 3bar(1bar=1kgf/cm2=0.1MPa)safety valve to prevent overburden for the tube.
10. Micro negative pressure sealing combustion, which will not consume indoor air or pollute indoor air.
11. Fire will die out automatically when the flue gets blocked or there is downdraft, and it will display the security protection code to ensure the boiler is safe.
12. Condensing boiler is with pressure switch which can ensure that the boiler will not ignite when water or water pressure is in shortage.
13. It is with three minutes delay function to prevent damage caused by frequent turn-on, so as to prolong its working life.
14. Water pump will work for one minute when the boiler stops working for 24 hours continually.
15. Condensing gas boiler adopts electronic pressure sensor to inspect the system water pressure.
Diagram of China Residential Wall Mounted Boiler
A: Heating water outlet
R: Heating water inlet
G: Gas inlet
C: Shower water outlet
F: Cold water inlet
S: Condensing water outlet
Installation of China Residential Wall Mounted Boiler
Specifications of China Residential Wall Mounted Boiler
Model
|
Unit
|
Pre-mixed Condensing
|
24kw
|
30kw
|
Gas Type
|
LPG/NG
|
Rated Gas Pressure
|
pa
|
2800(LPG)/2000(NG)
|
Rated Heat Input
|
KM
|
24
|
30
|
Minimum Heat Input
|
KM
|
10.5
|
12.5
|
Rated Heat Output
|
KM
|
23.3
|
28.8
|
Minimum Heat output
|
KM
|
8.7
|
10.5
|
Efficiency Under Rated Heat input
|
%
|
96.5
|
96.5
|
Efficiency Under 30% Rated Heat input
|
%
|
94
|
94
|
Rated Heat Output
|
KM
|
23.3
|
28.8
|
Temp. Range Of High Temp. System
|
℃
|
30-80
|
Temp. Range Of Low Temp. System
|
℃
|
30-55
|
Maximum pressure Of Low Temp. System
|
bar
|
3(0.3Mpa)
|
Expansion Tank Capacity
|
L
|
6
|
8
|
Preset Pressure Of Expansion Tank
|
bar
|
1(0.1Mpa)
|
Rated Hot Water supply
|
kg/min
|
13
|
15
|
Temp Range Of Shower Water Supply
|
℃
|
30-60
|
Comfortable Temp. Range Of water supply
|
℃
|
35-45
|
Application water pressure
|
bar
|
0.2-6(0.02-0.6Mpa)
|
The Minimum Starting Flow
|
L/min
|
2.1
|
The Minimum Closed Flow
|
L/min
|
1.8
|
Exhaust Type
|
|
Forced exhaust and Air supply type
|
Water Circulation Type
|
|
Airtight force circulation
|
Ignition Type
|
|
Pulse ignition
|
Thermostat Type
|
|
Proportional valve automatic constant temp.
|
Temp. Display Type
|
|
LCD
|
Power Supply
|
V/Hz
|
220-230/50Hz
|
Maximum Input Power
|
KM
|
110
|
Fuse
|
A
|
3.15
|
Insulation Grade
|
|
1
|
Electricity And Water Protection Grade
|
IP
|
IP44
|
Appearance Dimension: L×W×H
|
mm
|
740×410×328
|
Gas Input
|
Inch
|
G3/4
|
Connection For Heating Water Pipes
|
Inch
|
G3/4
|
Connection For Heating Water Pipes
|
Inch
|
G1/2
|
Air Input/Exhaust Duct
|
mm
|
100/60
|
Packing Size
|
mm
|
820×493×420
|
G.W./N.W.
|
kg
|
41.5/39
|
NO
|
PPM
|
80
|
Loading Q'ty20'/40'/40'HQ
|
sets
|
140/278/320
|