L24BL/ L30BL

L24BL/ L30BL

Introduction of Condensing Gas Boiler,

1. The temperature of the flue emission of condensing wall-hung boiler with a secondary heat exchanger is around 60℃. Temperature of an ordinary wall-hung boiler is generally above 160℃
2. At the bottom of the condensing gas boiler is a secondary heat exchanger and a condensing water drain. The condensing water drains from it during operation; while there is no condensing water drain in the ordinary wall-hung boiler
3. To distinguish a condensing gas boiler from others by the internal structure
(1) There is one condensing water pipe drain and a condensing water neutralization box
(2) There is a condensing water pipe drain and a condensing water neutralization box

Features of China Residential Wall Mounted Boiler

1. Condensing gas boiler has the function of timing reservation for one week.
2. It uses digital display of heating and water temperature, and large LCD screen to display working status.
3. Condensing boiler is with self-detection functions to indicate corresponding security protection code.
4. Control the strength of the fire as per the thermal load needs, so as to realize self control of hot water constant temperature.
5. Ionic fire failure protection function to ensure gas is cut off when fire fails.
6. Heating and circulating hot water adopt the same system, and they can interchange freely.
7. Protection against extreme temperature to prevent boiler getting too hot and damaged.
8. It is with automatic bypass protection function to supplement water when tube gets blocked through the bypass, so as to avoid heating without water.
9. Condensing gas boiler is with 3bar(1bar=1kgf/cm2=0.1MPa)safety valve to prevent overburden for the tube.
10. Micro negative pressure sealing combustion, which will not consume indoor air or pollute indoor air.
11. Fire will die out automatically when the flue gets blocked or there is downdraft, and it will display the security protection code to ensure the boiler is safe.
12. Condensing boiler is with pressure switch which can ensure that the boiler will not ignite when water or water pressure is in shortage.
13. It is with three minutes delay function to prevent damage caused by frequent turn-on, so as to prolong its working life.
14. Water pump will work for one minute when the boiler stops working for 24 hours continually.
15. Condensing gas boiler adopts electronic pressure sensor to inspect the system water pressure.

Diagram of China Residential Wall Mounted Boiler


Vanward
A: Heating water outlet
R: Heating water inlet
G: Gas inlet
C: Shower water outlet
F: Cold water inlet
S: Condensing water outlet


Installation of China Residential Wall Mounted Boiler



Vanward


Specifications of China Residential Wall Mounted Boiler

Model Unit Pre-mixed Condensing
24kw 30kw
Gas Type LPG/NG
Rated Gas Pressure pa 2800(LPG)/2000(NG)
Rated Heat Input KM 24 30
Minimum Heat Input KM 10.5 12.5
Rated Heat Output KM 23.3 28.8
Minimum Heat output KM 8.7 10.5
Efficiency Under Rated Heat input % 96.5 96.5
Efficiency Under 30% Rated Heat input % 94 94
Rated Heat Output KM 23.3 28.8
Temp. Range Of High Temp. System 30-80
Temp. Range Of Low Temp. System 30-55
Maximum pressure Of Low Temp. System bar 3(0.3Mpa)
Expansion Tank Capacity L 6 8
Preset Pressure Of Expansion Tank bar 1(0.1Mpa)
Rated Hot Water supply kg/min 13 15
Temp Range Of Shower Water Supply 30-60
Comfortable Temp. Range Of water supply 35-45
Application water pressure bar 0.2-6(0.02-0.6Mpa)
The Minimum Starting Flow L/min 2.1
The Minimum Closed Flow L/min 1.8
Exhaust Type
Forced exhaust and Air supply type
Water Circulation Type
Airtight force circulation
Ignition Type
Pulse ignition
Thermostat Type
Proportional valve automatic constant temp.
Temp. Display Type
LCD
Power Supply V/Hz 220-230/50Hz
Maximum Input Power KM 110
Fuse A 3.15
Insulation Grade
1
Electricity And Water Protection Grade IP IP44
Appearance Dimension: L×W×H mm 740×410×328
Gas Input Inch G3/4
Connection For Heating Water Pipes Inch G3/4
Connection For Heating Water Pipes Inch G1/2
Air Input/Exhaust Duct mm 100/60
Packing Size mm 820×493×420
G.W./N.W. kg 41.5/39
NO PPM 80
Loading Q'ty20'/40'/40'HQ sets 140/278/320
Related Products
  • GD4216S
  • GD4216S
    Nowadays, family gathering and parties are often held. Barbeque adds much fun, so a growing number of people take gas grill home. Our five burners outdoor gas grill is especially popular among customers, due to its large capacity and high performance. It is with CE and AGA certificate....